Dispositif pour la mesure des tensions de vapeur jusqu'à 20 kg/cm2 et 500° C
R. Bessouat, H. Chavanel et S. ElbergSection des Transferts Thermiques Centre d'Études Nucléaires de Grenoble
Abstract
The apparatus described here was built for the study of organic coolants for nuclear reactors. Its principle is based on a nul method. The device allows measurements up to 20 atmospheres and 500 °C. Results of measurements made with diphenyl, terphenyls OM2 and OMP and with Dowtherm A are given.
Résumé
L'appareil a été construit pour l'étude des fluides caloporteurs organiques utilisables dans les réacteurs atomiques. Son principe est basé sur une méthode de zéro. Le dispositif permet des mesures jusqu'à des pressions de 20 kg/cm 2 et des températures de 500 °C. Les résultats des essais effectués sur le diphényle, les terphényles OM2 et OMP et le dowtherm A sont fournis.