Abstract
Design of a kilocurie 60Co gamma ray source is described. Irradiation facilities are given both for research on radiation chemistry and photonuclear reactions. Cobalt samples were placed in six small cylinders in a lead drum. Dose-rates are indicated for various exposure chambers. The volume of the central exposure chamber is of 1 000 cc and the integral dose rate is of 2.108 rads. kilog/hour. Tubes or electrical leads connected to external apparatus can easily be introduced with the sample.
Résumé
On décrit les dispositifs d'irradiation et de protection installés pour recevoir 1 kilocurie de radiocobalt, destinés à des recherches sur les effets chimiques des rayonnements γ et sur les réactions photonucléaires. Les échantillons de cobalt radioactifs sont placés dans six petits cylindres fixes disposés selon un anneau enrobé dans un tambour de plomb. Les diverses possibilités d'irradiation sont décrites et on indique les doses intégrales par heure en diverses positions.
2320L - gamma transitions and level energies.
Key words
gamma ray spectra