Numéro
J. Phys. Phys. Appl.
Volume 23, Numéro S6, juin 1962
Page(s) 102 - 104
DOI https://doi.org/10.1051/jphysap:01962002306010200
J. Phys. Phys. Appl. 23, 102-104 (1962)
DOI: 10.1051/jphysap:01962002306010200

Amplification gazeuse dans un compteur proportionnel

Alain Lansiart et Jean-Pierre Morucci

Service d'Électronique Physique, Section d'Études des Appareils d'Électronique Physique, Centre d'Etudes Nucléaires de Saclay, France


Abstract
An explanation is suggested for the deviation from theory of random fluctuations in the multiplication phenomena when one primary electron is considered. It is proposed that the duplication factor α depends on the number of electrons already produced in the multiplication process. A curve is calculated using this assumption and is found to be in excellent agreement with the experiments of Curran, Cockroft and Angus [1].


Résumé
Une explication du désaccord entre la théorie et l'expérience des fluctuations statistiques dans le phénomène de multiplication gazeuse, quand on considère un seul électron primaire est suggérée. Il est proposé de relier le facteur de duplication α au nombre d'électrons déjà produits au cours du processus de multiplication. Une courbe, calculée avec cette hypothèse, se révèle en parfait accord avec les expériences de Curran, Cockroft et Angus.

PACS
07 - Instruments, apparatus, and components common to several branches of physics and astronomy.

Key words
Proportional counters -- Amplification